Flange Standard Guide

Flange Standards for Valve Buyers: ANSI, DIN, JIS and GB Compared

In short: "DN100 PN16" describes a nominal size and a pressure. It does not describe a flange. Bolt circle, bolt count, bolt diameter, flange thickness and facing are each specified in a different table depending on whether the plant was engineered to ASME B16.5, EN 1092 or JIS B2220. This guide explains what actually differs, why pressure classes are not interchangeable, and how to write the flange requirement so the valve bolts up on delivery.

1. Why Flange Mismatch Stops Projects

A valve is the one component in a pipe run that has to match two things at once: the pipe it sits in and the flanges it bolts to. Everything else can be worked around at site. A flange cannot. When the holes do not line up the options are a new spool piece, a pair of adaptor flanges or a valve reordered, and all three arrive after the original schedule.

The failure usually sits between two documents. The datasheet says "DN100, PN16, flanged"; the piping drawings are to ASME B16.5 Class 150; the site store holds inch studs. Nothing on the datasheet is wrong and the valve that arrives is exactly what was ordered. It still will not fit, and the goods conformed to the purchase order, so the cost lands on the buyer.

Re-drilling on site is worse than the delay: enlarging a bolt hole reduces the flange section, changes the bearing area under the nut and creates a non-conformance no inspector will sign off. The fix costs one line on an RFQ, written before the order.

2. The Three Flange Families

International procurement deals with three live families and two legacy ones. The table is deliberately qualitative: its job is to place a project in the right system, not to replace the dimensional tables.

Family Pressure designations Bolt pattern character Where it is standard practice
ASME B16.5 (steel, alloy) Class 150 to 2500 Inch bolting, class-based circle and thickness North America, Middle East oil and gas, Latin America
ASME B16.1 (cast iron) Class 25, 125, 250 Iron flange tables; not a B16.5 class Legacy North American water and HVAC iron piping
EN 1092-1 / 1092-2 PN6 to PN40 Metric bolting, PN-based tables, defined facing types Europe, CIS-influenced projects, international water tenders
JIS B2220 5K, 10K, 16K, 20K, 30K Metric bolting on a Japanese pattern Japan, Korea, Taiwan, Southeast Asian marine work
GB/T series PN2.5 to PN40 in common water duty Metric bolting, PN system with national detail Chinese domestic projects and Chinese-designed plants abroad
BS 4504 / BS 10 (legacy) PN designations; table letters Superseded patterns still on old drawings Existing plants and refurbishment, not new design

Two clarifications worth carrying into a meeting. Class 125 is an ASME B16.1 cast iron designation, not a B16.5 pressure class: in small sizes a Class 125 iron flange can share a bolt pattern with a Class 150 steel flange, but thickness, facing and material limits come from different tables. And EN 1092 is split by material — EN 1092-1 for steel, EN 1092-2 for cast iron — so a ductile iron valve body is dimensioned to the cast iron part.

ISO 7005 sits behind much of this, and national standards that derive from it are usually compatible but not identical. Compatibility claims always need the table, never the family name.

3. Pressure Class Equivalence Myths

The most damaging piece of folklore in valve procurement is the table that says Class 150 equals PN16 and Class 300 equals PN40. It survives because it is roughly true in the one place people check it — ambient-temperature water — and wrong everywhere else.

The two systems do not measure the same thing. An ASME class is a reference designation whose allowable pressure is read from a material-specific rating table and falls as temperature rises. A PN number is a nominal pressure with its own material groups and derating curve. A Class 150 carbon steel flange is rated a little under 20 bar at 38°C; a PN16 flange is rated 16 bar at its reference condition. Close enough to be confused, different enough that the numbers do not transfer.

Two consequences follow. A valve cannot be converted from one system to the other by changing the marking — the casting is machined to one drilling and that is what ships. And conversion tables in sales literature are a statement about pressure capability, never about dimensions.

Drilling is a build option on the product, not an afterthought: our 500X pressure reducing valve is offered to ANSI, JIS or GB drilling, and the Z41X flanged gate valve is built at PN10 or PN16. Either way the option has to be on the order; nothing at the packing stage recovers a drilling that was never specified.

4. What Actually Differs

Five features decide whether two flanges mate. They are the questions to ask when comparing a datasheet against a piping drawing.

  • Bolt circle (PCD). The diameter through the hole centers, and the dimension most often assumed to be common. Our published Z41X table lists it as the D1 column: DN100 shows 180 mm with eight 18 mm holes. Compare against that kind of table, not a conversion chart.
  • Bolt count. DN100 uses eight bolts in both ASME Class 150 and EN 1092-2 PN16, which is exactly why the error is common — the count matches, so the flange looks right until a stud is offered to the hole.
  • Bolt diameter and thread. Inch studs in the ASME series, metric in EN, JIS and GB. A 5/8" stud will not pass a 16 mm hole at the intended bearing stress.
  • Thickness and outside diameter. Even where drilling coincides, plate thickness differs, and thickness controls how bolt load reaches the gasket.
  • Facing. Raised face, flat face or ring joint, with the height and seating width defined separately in each standard.

Inspection follows from that list: count the holes, measure hole diameter, bolt circle across opposite holes, outside diameter, thickness and facing height, then compare with the table for the marking on the flange. Better still, trial-fit one valve to a mating spool from site stock. Marking is the other half of the check — standard, class or PN, size, material and heat number. If the marking is painted over, the item cannot be tied to its certificate.

5. Gaskets and Bolting

The flange is half a joint. The other half is chosen to suit it, and the two common site failures — a weep at hydrotest and a gasket that extrudes after a thermal cycle — usually trace to a gasket or bolting decision made separately from the flange decision.

For raised-face steel flanges, a spiral-wound gasket with inner and outer rings is the default in most plant specifications, dimensioned to the gasket standard that matches the flange series. Flat-face cast iron flanges take a full-face gasket whose bolt holes must align with the pattern, so the gasket has to be ordered for the same standard as the valve. Rubber-lined wafer valves seal on the liner, but still need clean, flat faces free of weld spatter. Ring-joint gaskets need a matching groove, and a groove cannot be improvised on site.

Bolting follows the same logic: carbon steel studs with heavy hex nuts for steel flanges, stainless where corrosion or the client specification requires it. What matters at assembly is sequence and control — cross pattern, staged, to a torque taken from the gasket manufacturer's table for that size and material, with a defined lubricant. A generic torque figure from a chart for a different gasket is worse than no figure, because it looks authoritative. Bolts are not reused after a pressure joint is broken.

Two details cause disproportionate trouble. Coating on a flange face changes the gasket seating condition, so faces should be masked during painting — which is also why a valve painted after testing is worth a question. And protection caps must actually be removed: one left inside a flange becomes a downstream obstruction, and on a fire main a blocked riser.

6. The RFQ Clause and Receiving Inspection

A flange requirement that survives a factory, a forwarder and a site store is short and specific. Anything less leaves the supplier to interpret, and a supplier interpreting a gap will choose the drilling it makes most often.

  • Standard and edition. ASME B16.5, EN 1092-2 or JIS B2220, with the year where the project document names one.
  • Class, not a conversion. Class 150 or PN16 — never "150 lb / PN16 equivalent".
  • Size in both systems. DN100 (NPS 4), so nobody has to guess the mapping.
  • Facing. Raised face, flat face or ring joint, with a height tolerance if the project has one.
  • Bolting. Inch or metric, and the stud grade where specified.
  • Prohibitions. No enlargement or slotting of bolt holes, no field re-drilling, faces masked during coating.
  • Evidence. Dimensional record per size, material certificate, and a photograph of the marking on a sample.

Receiving inspection then has a checklist rather than a judgement call, and the measurements are recorded so a repeat order can be compared against them. Two guides go further on the surrounding decisions: the B2B valve sourcing checklist covers the document package for a shipment, and the fire hydrant valve standards guide explains how hose connection standards differ again from pipeline drilling. Flanged ancillaries carry the same decision — the SGL41H telescopic Y-strainer and the SP45F balancing valve must be ordered to the same standard as the valves beside them.

Frequently Asked Questions

Is a PN16 flange the same as a Class 150 flange? +

No. Both are common for DN50 to DN200 water service and both are loosely called "16 bar", but they are separate dimensional systems. Bolt circle, flange thickness, facing detail and bolting thread are specified in different standards, so a Class 150 valve will not necessarily bolt to a PN16 pipe flange. Quote the standard, the class and the thread on the order.

Can I use the same gasket for an ANSI and a DIN flange of the same size? +

Only if the gasket is dimensioned for both. A gasket sized for an ASME raised face has a different outside diameter and thickness from one sized for an EN raised face, and a flat-face cast iron flange needs a full-face gasket rather than a raised-face type. Match facing type and gasket standard, not just nominal size.

Why does JIS 10K look similar to PN16 but not fit? +

JIS B2220 uses its own bolt circle, bolt size and thickness tables, sized in millimetres on a pattern that follows neither EN 1092 nor ASME. In some sizes the bolt count matches a PN16 flange, which is what makes the error easy: the holes line up by eye but the circle or the bolt diameter is wrong. JIS 10K is routine in Japan, Korea, Taiwan and much of Southeast Asian marine and plant work.

Are DN and NPS interchangeable? +

For the common sizes the nominal bores correspond — DN50 is NPS 2, DN100 is NPS 4 — but DN is a rounded metric designation, so the actual bore and wall follow the schedule or series rather than the label. The practical risk is not DN versus NPS; it is assuming the flange drilling follows from the nominal size alone. It does not.

What if the bolt holes almost line up on site? +

Do not ream, slot or drill them out. Enlarging a hole reduces the flange section, changes the bearing area under the nut and is a non-conformance against every flange standard. The correct answers are a correctly drilled spool piece, a companion flange, or a pair of flanges ordered to the right standard. A supplier offering to "open the holes a little" is telling you something about the whole order.

Which flange standard should I specify for an export project? +

Follow the standard the piping was engineered to: ASME B16.5 for North American work and much of the Middle East and Latin America, EN 1092 for Europe and CIS-influenced designs, JIS B2220 for Japanese-influenced plants and marine work, GB/T for Chinese projects. The designer and client specification decide; a supplier should match the drawing, not convert it.

Need Valves Drilled to Your Flange Standard?

Send the flange standard, class, size and bolting thread from your piping drawings — we confirm the drilling, the gasket interface and the dimensional record before production.

Contact Us