Dry Alarm Valve (ZSFC Series)
The ZSFC dry alarm valve is the core control valve for dry-pipe and pre-action sprinkler systems. It stays closed by air (or nitrogen) pressure on the system side while the water side is held full, and opens automatically when an actuated sprinkler releases the system air, letting water fill the dry piping and reach the discharging sprinkler. Ideal for unheated buildings, cold-climate warehouses and pre-action systems.
Key Features
- Air-pressure operated clapper for a reliable closed state in dry and pre-action systems
- Instant opening when system air is released by an actuated sprinkler
- Integrated alarm mechanism with delay chamber and water-motor gong for early warning
- Heavy-duty ductile iron body rated for the full dry-pipe pressure cycle
- Flanged connections available in DN100 - DN200
Technical Specifications
- Size Range
- DN100 / DN150 / DN200 (ZSFC100 / ZSFC150 / ZSFC200)
- Nominal Pressure
- 1.6 MPa (PN16)
- System Side
- Air / Nitrogen (0.03 - 0.05 MPa typical)
- Connection Type
- Flanged
- Accessory
- Delay Chamber, Water-Motor Alarm Gong, Pressure Gauges
Parts & Materials List
- Valve Body
- Ductile Iron (QT450)
- Clapper / Seat
- EPDM / NBR Covered Ductile Iron
- Delay Chamber
- Cast Iron / Brass
- Alarm Gong
- Aluminum Alloy
- Trim & Fittings
- Galvanized Steel / Brass
Applications
- Automatic sprinkler systems
- Commercial and residential buildings
- Industrial warehouses
- High-hazard deluge and pre-action systems
Quality & Testing
Pressure and leakage testing per GB 5135 series; alarm sensitivity verified with flow switches and alarm gongs.
Frequently Asked Questions
What is the difference between a dry alarm valve and a wet alarm valve (ZSFZ)?
What sizes is the ZSFC dry alarm valve available in?
What alarm devices come with the ZSFC valve?
Can the ZSFC be used in a pre-action system?
Related Buying Guides
Fire Sprinkler Control Valve Types: OS&Y, Butterfly & Check Valves
The role of each control valve in a sprinkler system and how OS&Y, butterfly and check valves work together.
Read Guide Buying GuideFire Sprinkler Systems: Wet, Dry or Pre-action?
Compare wet, dry and pre-action sprinkler configurations to match the hazard class of your building.
Read GuideRelated Products
Sprinklers & Alarm Valves Deluge Alarm Valve Group (ZSFM Series)
View Details
Sprinklers & Alarm Valves ESFR Early Suppression Fast Response Sprinkler
View Details
Sprinklers & Alarm Valves Glass Bulb Fire Sprinkler (ZST Series)
View Details
Sprinklers & Alarm Valves