Dry Alarm Valve (ZSFC Series)
Sprinklers & Alarm Valves

Dry Alarm Valve (ZSFC Series)

The ZSFC dry alarm valve is the core control valve for dry-pipe and pre-action sprinkler systems. It stays closed by air (or nitrogen) pressure on the system side while the water side is held full, and opens automatically when an actuated sprinkler releases the system air, letting water fill the dry piping and reach the discharging sprinkler. Ideal for unheated buildings, cold-climate warehouses and pre-action systems.

Key Features

  • Air-pressure operated clapper for a reliable closed state in dry and pre-action systems
  • Instant opening when system air is released by an actuated sprinkler
  • Integrated alarm mechanism with delay chamber and water-motor gong for early warning
  • Heavy-duty ductile iron body rated for the full dry-pipe pressure cycle
  • Flanged connections available in DN100 - DN200

Technical Specifications

Size Range
DN100 / DN150 / DN200 (ZSFC100 / ZSFC150 / ZSFC200)
Nominal Pressure
1.6 MPa (PN16)
System Side
Air / Nitrogen (0.03 - 0.05 MPa typical)
Connection Type
Flanged
Accessory
Delay Chamber, Water-Motor Alarm Gong, Pressure Gauges

Parts & Materials List

Valve Body
Ductile Iron (QT450)
Clapper / Seat
EPDM / NBR Covered Ductile Iron
Delay Chamber
Cast Iron / Brass
Alarm Gong
Aluminum Alloy
Trim & Fittings
Galvanized Steel / Brass

Applications

  • Automatic sprinkler systems
  • Commercial and residential buildings
  • Industrial warehouses
  • High-hazard deluge and pre-action systems

Quality & Testing

Pressure and leakage testing per GB 5135 series; alarm sensitivity verified with flow switches and alarm gongs.

Frequently Asked Questions

What is the difference between a dry alarm valve and a wet alarm valve (ZSFZ)?
A wet alarm valve protects a system whose pipes are always full of water. A dry alarm valve (ZSFC) protects a dry-pipe system whose water side is full but the pipe network is held under air pressure and empty of water, so it stays shut until a sprinkler opens and releases the air. Use ZSFC where the protected space can freeze or where pre-action dual-protection is required.
What sizes is the ZSFC dry alarm valve available in?
The ZSFC is available in DN100, DN150 and DN200 (models ZSFC100 / ZSFC150 / ZSFC200) with a 1.6 MPa nominal rating and flanged connections, covering the majority of dry-pipe and pre-action installations.
What alarm devices come with the ZSFC valve?
The valve group includes the delay chamber, a water-motor alarm gong, and inlet and outlet pressure gauges so operators can confirm both the air pressure on the system side and water pressure on the supply side at a glance.
Can the ZSFC be used in a pre-action system?
Yes. The ZSFC dry alarm valve is used as the water control valve in pre-action systems, working with a pre-action control device so water only enters the dry piping after both the sprinkler and the detection system actuate.