Warehouse Sprinkler Systems — Factory Direct
ESFR Sprinkler Heads for High-Pile Warehouse Protection
ESFR sprinkler heads are selected when a warehouse design needs fast, high-volume ceiling discharge for storage protection. Wanlian supplies the ESFR head and the monitored valves, alarm and flow components around it, so the approved design can be quoted as one coordinated package.
ESFR Sprinkler and System Components
ESFR Early Suppression Fast Response Sprinkler
ESFR-202 / ESFR-242 / ESFR-363, 74°C, pendent & upright
Glass Bulb Fire Sprinkler (ZST Series)
DN15 / DN20, K=80 ±4 / K=115 ±9, pendent / upright / sidewall
Wet Alarm Check Valve ZSFZ 150
DN100 / DN150 / DN200, 1.6 MPa, alarm gong and retard chamber
Vane Type Water Flow Indicator (ZSJZ Series)
DN50–DN200, 1.2 / 1.6 MPa, adjustable 2–60 s delay
Signal Butterfly Valve (DN80 PN16)
DN50–DN300, PN16, monitored open/closed position
UL/FM Fire Protection Resilient Seated OS&Y Gate Valve
2"–10", grooved ends, rising stem, UL / FM listed
ESFR Selection and Specification
| Selection point | Verified product information |
|---|---|
| ESFR head | ESFR-202 / ESFR-242 / ESFR-363 and ZSTX-161; 74°C; pendent PY or upright UY; R1/2" or R3/4" NPT. |
| Hydraulic planning | Use the approved storage design to establish K-factor, operating pressure, water demand and head spacing before release. |
| Standard sprinkler option | ZST glass bulb heads: DN15 / DN20, K=80 ±4 or K=115 ±9, with pendent, upright and sidewall types. |
| Alarm and flow | ZSFZ wet alarm valve: DN100 / DN150 / DN200 at 1.6 MPa; ZSJZ flow indicator: DN50–DN200 at 1.2 / 1.6 MPa. |
| Isolation and monitoring | Signal butterfly valve: DN50–DN300, PN16, with integrated electrical signal switch; OS&Y gate valve: 2"–10", grooved, UL / FM listed. |
What to Include in One ESFR Order
- Approved head schedule — storage commodity, rack and ceiling information, head model, orientation, thread and quantity.
- Hydraulic design basis — selected K-factor, design pressure, water demand and the project standard or AHJ comments.
- System control set — wet alarm check valve, water-flow indicators and the specified monitored isolation valves.
- Documentation and packing — product data, required certificates, box quantities and destination-market marking confirmed before production.
ESFR Design Resources
For design decisions, see the ESFR sprinkler system guide, fire sprinkler head selection guide and fire sprinkler system valves guide.
Frequently Asked Questions
What is an ESFR sprinkler?+
ESFR means Early Suppression Fast Response. The ESFR head in this range uses a high-flow design, a 74°C fast-response glass bulb and pendent or upright orientations for high-pile storage, warehouses and industrial facilities.
Can ESFR sprinklers replace in-rack sprinklers?+
They can in storage arrangements that satisfy the applicable design criteria. The final decision depends on commodity, storage height, ceiling height, rack layout, K-factor and design pressure, so the fire protection designer and AHJ must approve the arrangement.
How does K-factor affect ESFR selection?+
K-factor and operating pressure determine the water delivered by each head. Use the hydraulic calculation and storage criteria to select the ESFR model; do not choose a head from nominal pipe size alone.
What temperature rating does the ESFR head use?+
The ESFR product is specified with a 74°C (165°F) fast-response glass bulb. Confirm ambient conditions and the required listing or approval for the destination project before ordering.
What should be included in an ESFR sprinkler package?+
A typical order starts with the head schedule and adds the selected sprinkler heads, wet alarm check valve, water-flow indicators, monitored isolation valves and any standard system accessories required by the approved design.
Can you quote the complete warehouse sprinkler BOM?+
Yes. Send the approved head schedule, storage and ceiling information, hydraulic design data and valve schedule. We can quote the verified heads and system components as one project package.
Need an ESFR Warehouse Sprinkler Package?
Send the head schedule and hydraulic design basis — we will confirm the component list and reply with a coordinated quotation within 12 hours.