Pump Room Valves and Fire Department Connections
Fire Pump Adapter and Pump Room Valve Packages
The fire pump room is more than the pump: it is the suction, discharge, check, isolation and test arrangement that lets the pump supplier’s fire pump set operate safely and lets the fire department add water through a compatible Siamese connection. Wanlian supplies the surrounding valves and connections; the fire pump set is by others.
Fire Pump Connection Components
SQD100-1.6 Fire Pump Adapter (Siamese Connection)
2 × DN65 inlets, DN100 flanged outlet, 1.6 MPa
UL/FM Fire Protection Resilient Seated OS&Y Gate Valve
2"–10", grooved ends, rising stem, UL / FM listed
Ductile Iron Resilient Seat Flanged Gate Valve (Z41X)
DN50–DN700, PN10 / PN16, ductile iron, flanged
Spherical Cast Iron Ball Check Valve (HQ44X-16)
DN50–DN400, PN16, non-blocking EPDM ball
Hydraulic Adjustable Pressure Reducing Valve (500X)
DN20–DN600, 0.1–1.6 MPa adjustment, hydraulic pilot
Pump Room Selection Table
| Arrangement | Verified selection reference |
|---|---|
| Fire department connection | SQD100-1.6: two DN65 inlets with SQS65 / KWS65 caps, DN100 flanged outlet, 1.6 MPa, integrated control valve. |
| Isolation valves | UL/FM OS&Y gate valve: 2"–10", grooved ends, rising stem; Z41X flanged gate valve: DN50–DN700, PN10 / PN16. |
| Discharge check | HQ44X spherical ball check valve: DN50–DN400, 1.6 MPa (PN16), non-blocking flow channel and EPDM / NBR sealing. |
| Pressure management | 500X hydraulic pressure-reducing valve: DN20–DN600; adjustment range 0.1–1.6 MPa; confirm its role in the approved downstream design. |
| Pump and test data | Provide pump supplier flow/head data, pipe sizes, test arrangement and applicable approval requirements before final valve sizing. |
What to Include in One Pump-Room Order
- Connection point — Siamese inlet standard, outlet flange, cap arrangement and fire department interface.
- Suction and discharge set — isolation valve, check valve and any pressure-control item matched to the approved piping schedule.
- Test and commissioning details — test header or test outlet arrangement, instruments by others where applicable, and the pump supplier’s certified curve.
- Submittal package — drawings, product data, certificates, connection dimensions, pressure class and destination-market marking.
Pump Room Design Resources
Use the fire pump room valves guide for suction, discharge and test planning, the Siamese fire department connection guide, and the check valve types guide when preparing the valve schedule.
Frequently Asked Questions
Do you supply the fire pump itself?+
No. Wanlian supplies the adapter, valves and related connection equipment around the fire pump set by others. The pump supplier provides the pump selection and certified curve; we use those project inputs to coordinate the surrounding components.
What is a Siamese fire pump adapter?+
The SQD100-1.6 Fire Pump Adapter is a fire department Siamese connection with two DN65 inlets and one DN100 flanged outlet, plus an integrated control valve, for fire-engine water supply into the fire protection network.
Which valve belongs on the pump suction side?+
The suction arrangement is set by the approved pump-room design and the authority having jurisdiction. Isolation is normally kept fully open during pump operation; confirm the selected valve type, size and connection with the pump supplier and designer.
Where does the discharge check valve go?+
The discharge check valve is coordinated between the fire pump set by others and the discharge isolation valve to limit backflow. The final location, size and pressure class follow the approved piping layout and pump supplier data.
Can a pressure-reducing valve replace pump controls?+
No. The 500X is a hydraulic pressure-reducing valve for managing downstream pressure in a water line; it is not a substitute for the fire pump controller, pump relief arrangement or the pump supplier’s certified system design.
What information should I send for a pump-room package quote?+
Send the pump supplier’s flow and head data, suction and discharge pipe sizes, connection standards, test arrangement, fire department inlet standard, required certifications and the valve schedule or drawings.