Sprinkler Systems
Wet alarm valves, deluge valves, pre-action systems, sprinkler heads and flow indicators for automatic sprinkler protection in commercial and industrial buildings.
Guides & Articles
Pre-Action Valve (ZSFY) Guide: Interlock, Trim, Sizing and Nuisance Trips
How a ZSFY pre-action valve works and how to specify one: interlock arrangement, air-side trim, DN80-DN250 sizing, commissioning, nuisance trips and the RFQ lines.
In This Guide
- 01 1. What the Empty Pipe Is Buying You
- 02 2. Single-Interlock, Double-Interlock and Dry-Pipe Pre-action
- 03 3. How the ZSFY Group Holds Closed and Trips
Dry Alarm Valve (ZSFC) Selection & Installation Guide
How a ZSFC dry alarm valve works, dry-pipe vs wet and pre-action selection, sizing, air maintenance, freeze protection, nuisance trips and RFQ data.
In This Guide
- 01 1. When a Dry-Pipe System Is the Right Answer
- 02 2. How the ZSFC Dry Alarm Valve Holds Closed and Trips
- 03 3. Dry Alarm Valve vs Wet Alarm Valve vs Pre-action
Deluge Valve Sizing and Selection Guide (2026)
How a ZSFM deluge valve works, how to size it for flow and trip time, actuation options, open-head and monitor layouts, testing and RFQ data.
In This Guide
- 01 1. When a System Needs Deluge Protection
- 02 2. How the ZSFM Deluge Valve Group Works
- 03 3. Choosing the Actuation Method
Foam Deluge and Foam-Water Spray Systems Guide (2026)
Foam deluge and foam-water spray systems for Class B risks: deluge valve, proportioning options, concentrates, discharge devices and field testing.
In This Guide
- 01 1. When Foam Beats Water
- 02 2. Anatomy of a Foam Deluge System
- 03 3. Proportioning Options Compared
Water Flow Indicator Guide: Wet Sprinkler Flow Switches
Specify a water flow indicator for wet sprinkler systems: vane construction, branch and riser mounting, delay settings, panel wiring, testing and RFQ data.
In This Guide
- 01 1. Why Flow Detection Is Separate from the Alarm Valve
- 02 2. How a Vane-Type Indicator Works
- 03 3. Indicator, Flow Switch and Pressure Switch Compared
ESFR Sprinkler System Guide: K-Factor, Storage Height & Design (2026)
How ESFR sprinklers suppress high-pile storage fires without in-rack sprinklers: K-factor selection, design pressure, ceiling and storage limits, and the valves a warehouse system needs.
In This Guide
- 01 What an ESFR System Actually Does
- 02 ESFR vs Standard Sprinklers
- 03 K-Factor, Pressure and Storage Height
Fire Sprinkler System Valves: Selection & Engineering Guide (2026)
How ZSFZ wet alarm, ZSFM deluge, ZSFY pre-action valves and ZSJZ flow indicators work — and when to specify each for your sprinkler system.
In This Guide
- 01 1. Wet-Pipe Systems: The ZSFZ Wet Alarm Valve
- 02 2. Deluge Systems: The ZSFM Deluge Valve
- 03 3. Pre-Action Systems: The ZSFY Dual-Trigger Valve
Fire Sprinkler Systems: Wet, Dry or Pre-action? (2026 Guide)
A practical comparison of wet, dry and pre-action systems, how to select sprinkler heads (K-factor, temperature, response) and the components your BOM needs.
In This Guide
- 01 1. The Three System Types Compared
- 02 2. Choosing Sprinkler Heads
- 03 3. The Components Your BOM Needs
Fire Sprinkler Control Valve Types: OS&Y, Butterfly & Check Valves
OS&Y gate, signal butterfly and check valve duties in sprinkler systems, plus a control valve comparison table and a UL/FM specification checklist for B2B buyers.
In This Guide
- 01 1. What Fire Sprinkler Control Valves Do
- 02 2. OS&Y Gate Valves: Monitored Main Isolation
- 03 3. Signal Butterfly Valves for Section Control
Fire Sprinkler Head Selection Guide: K-Factor, Temperature & Response (2026)
How to select fire sprinkler heads: K-factor and flow (K=80/K=115), temperature ratings and bulb colour coding, quick vs standard response, pendent/upright/sidewall/concealed orientation and UL listing in the NFPA 13 context.
In This Guide
- 01 1. Start With the System Type, Then the Head
- 02 2. K-Factor and Flow: Matching Water Delivery
- 03 3. Temperature Ratings and Bulb Colour Coding
Commercial Building Sprinkler System BOM: Complete Procurement Guide (2026)
Complete BOM for a commercial building sprinkler system: alarm valve groups, OS&Y & signal valves, siamese, sprinkler heads, flow indicators — one package, one PO, verified.
In This Guide
- 01 1. Why the Sprinkler Package Is Procured as One Scope
- 02 2. The Alarm Valve Group: Heart of the Wet System
- 03 3. Monitored Isolation: OS&Y and Signal Butterfly Valves
Fire Valve Maintenance & Spare Parts Guide for B2B Buyers
Fire valve maintenance and spare parts for B2B buyers: wear parts, exercise testing, alarm valve servicing, spares kits and the RFQ lines that matter.
In This Guide
- 01 1. Serviceability Is Bought at the Order Stage
- 02 2. What Actually Wears in Fire Valves
- 03 3. Four Maintenance Levels: Inspection, Operation, Internal, Overhaul
Related Products
Sprinklers & Alarm Valves Wet Alarm Check Valve ZSFZ 150
View Details
Sprinklers & Alarm Valves Glass Bulb Fire Sprinkler (ZST Series)
View Details
Sprinklers & Alarm Valves Deluge Alarm Valve Group (ZSFM Series)
View Details
Sprinklers & Alarm Valves Pre-action Deluge Alarm System (ZSFY Series)
View Details
Sprinklers & Alarm Valves Vane Type Water Flow Indicator (ZSJZ Series)
View DetailsNeed Help with Sprinkler Systems?
Our engineers help you select the right products for your project specification.
Ask an Engineer